Lifesafety PowerMercury ProWire ProWire Power System combine FlexPower modules alongside preview access control hardware in one compact and secure UL listed solution. ProWire system are prewired for power to the access control modules, faults, tamper switch, lock control wiring (where applicable) and communication. Standard ProWire features include: Built in Fire Alarm disconnect unlocks doors on a fire alarm Low battery cutoff protects batteries from deep discharge Dedicated fast charger prolongs battery life Enhanced surge immunity for input/output protection Locksafe optimized voltages provide longterm lock protection OutSmart Visual LED notification (12V/Green, 24V/Blue) Network ready with optional Netlink module Monitor power supply and battery in NetLink dashboard Remote test batteries Lifetime Warranty LifeSafety Power's quality commitment SYSTEM DETAILS FPO150/250 Dual Voltage Power 400W Total Output, 120 VAC Input, AC Fault and System Fault form C contacts may be triggered by low/no battery, short to earth ground, power supply failure, or blown fuse 3 D8P 24 Auxiliary Outputs 2.5A Class 2 Power Limited Outputs, dual buss voltage selection by zone, OutSmart dual color LEDs 2 C8P 16 Relay Lock Outputs 2.5A Class 2 power limited outputs, programmable for failsafe/failsecure, FAI, NC/NO input, voltage or dry output per zone. Dual buss voltage selection by zone, OutSmart dual color LEDs E8M2/P16-B Enclosure Size: 36.0H x 30.0W x 6.5D in (91.44 x 76.2 x 16.51 cm) Enclosure 16 Doors, Panduit, Prewired for one LP2500 and eight MR52 boards System Weight 64.05 lbs (29.05kg)
Category:
Power & Hardware
Lifesafety PowerPower & Hardware

Mercury ProWire ProWire Power System combine FlexPower modules alongside preview access control hardware in one compact and secure UL listed solution. ProWire system are prewired for power to the access control modules, faults, tamper switch, lock control wiring (where applicable) and communication. Standard ProWire features include: Built in Fire Alarm disconnect unlocks doors on a fire alarm Low battery cutoff protects batteries from deep discharge Dedicated fast charger prolongs battery life Enhanced surge immunity for input/output protection Locksafe optimized voltages provide longterm lock protection OutSmart Visual LED notification (12V/Green, 24V/Blue) Network ready with optional Netlink module Monitor power supply and battery in NetLink dashboard Remote test batteries Lifetime Warranty LifeSafety Power's quality commitment SYSTEM DETAILS FPO150/250 Dual Voltage Power 400W Total Output, 120 VAC Input, AC Fault and System Fault form C contacts may be triggered by low/no battery, short to earth ground, power supply failure, or blown fuse 3 D8P 24 Auxiliary Outputs 2.5A Class 2 Power Limited Outputs, dual buss voltage selection by zone, OutSmart dual color LEDs 2 C8P 16 Relay Lock Outputs 2.5A Class 2 power limited outputs, programmable for failsafe/failsecure, FAI, NC/NO input, voltage or dry output per zone. Dual buss voltage selection by zone, OutSmart dual color LEDs E8M2/P16-B Enclosure Size: 36.0H x 30.0W x 6.5D in (91.44 x 76.2 x 16.51 cm) Enclosure 16 Doors, Panduit, Prewired for one LP2500 and eight MR52 boards System Weight 64.05 lbs (29.05kg)

Mercury ProWire ProWire Power System combine FlexPower modules alongside preview access control hardware in one compact and secure UL listed solution. ProWire system are prewired for power to the access control modules, faults, tamper switch, lock control wiring (where applicable) and communication. Standard ProWire features include: Built in Fire Alarm disconnect unlocks doors on a fire alarm Low battery cutoff protects batteries from deep discharge Dedicated fast charger prolongs battery life Enhanced surge immunity for input/output protection Locksafe optimized voltages provide longterm lock protection OutSmart Visual LED notification (12V/Green, 24V/Blue) Network ready with optional Netlink module Monitor power supply and battery in NetLink dashboard Remote test batteries Lifetime Warranty LifeSafety Power's quality commitment SYSTEM DETAILS FPO150/250 Dual Voltage Power 400W Total Output, 120 VAC Input, AC Fault and System Fault form C contacts may be triggered by low/no battery, short to earth ground, power supply failure, or blown fuse 3 D8P 24 Auxiliary Outputs 2.5A Class 2 Power Limited Outputs, dual buss voltage selection by zone, OutSmart dual color LEDs 2 C8P 16 Relay Lock Outputs 2.5A Class 2 power limited outputs, programmable for failsafe/failsecure, FAI, NC/NO input, voltage or dry output per zone. Dual buss voltage selection by zone, OutSmart dual color LEDs E8M2/P16-B Enclosure Size: 36.0H x 30.0W x 6.5D in (91.44 x 76.2 x 16.51 cm) Enclosure 16 Doors, Panduit, Prewired for one LP2500 and eight MR52 boards System Weight 64.05 lbs (29.05kg) available through HTS.

SKU
FPO150/250-2C8P3D8PE8M2/P16-B
MSRP$4,387.00
Our price$2,895.02
Save $1,491.98(34.01% off)
Backorder

More than a box on a truck.

  • Pre-configured before it shipsPre-configured to your network spec before it ships — VLANs, PoE budgets, firmware set, not left to you to sort out.
  • One support line, end to endOne support line, not a manufacturer RMA queue — the team that configures it is the team you call.
  • Professional installation availableProfessional installation and site turn-up available from the HTS field team.
  • One vendor across your networkOne vendor, one invoice, one point of accountability across your whole network.
Add to quote workspaceVolume pricing, deployment services, and verified availability confirmed upon request.